Single panel

Description
It is a panel made of expanded polystyrene (E.P.S.) with wire mesh mat from each side assembled with wire connectors, providing equal distribution of loads around the entire perimeter for high seismic resistance. The shape and the thickness may vary according to the needs.

Application

  • Structural elements for building up to 3– 4 floors
  • Walls
  • Roofs

Characteristics

Fire resistance: M1
Material type: (F) auto extinguishing
Sound transmission class: 38dB.
Thermal conductivity factor: K.

Panel K(W/m2° C) Panel K(W/m2° C)
PS 40 0,769 PS 130 0,268
PS 50 0,636 PS 140 0,250
PS 60 0,543 PS 150 0,234
PS 70 0,474 PS 160 0,220
PS 80 0,420 PS 170 0,208
PS 90 0,377 PS 180 0,197
PS 100 0,342 PS 190 0,187
PS 110 0,313 PS 200 0,178
PS 120 0,289
Double panel

Description

Two single panels with internal and external mesh, assembled through connectors, the concrete is poured on site.The thickness of the core concrete will be defined on the basis of the structural requirements.The outside panel is finished using standard concrete plaster.

Application
These panels are used to build walls for multi floor constructions, with special insulation and structural requirements. The double panel is usually needed for considerable number of floors. It is always based on structural studies.
Characteristics

Fire resistance: M1
Material type: (F) auto extinguishing
Sound transmission class: 45dB.
Thermal conductivity factor: K : 0,47 w/m²°c (Int. Thk. 40mm / Ext. Thk. 60mm)

High Strength panels

Description
It can be either a single or a double panel with extra reinforcement steel bars, added to the existing wire mesh; such panel is used for high strength requirements.

Application
Used as bearing wall for special constructions where resistance is required.
Characteristics

Fire resistance: M1
Material type: (F) auto extinguishing
Sound transmission class: 38dB to 45dB.
Thermal conductivity factor: K : 0,47 w/m²°c (Int. Thk. 40mm / Ext. Thk. 60mm)

Roof panel

Description

It is special shape expanded polystyrene panel allowing the reinforcing steel to be placed inside the beams and poured with concrete on site.

Application

Used for floor slabs and roofs with variable thickness according to the span.

Characteristics

Fire resistance: M1
Material type: (F) auto extinguishing
Sound transmission class: 45dB.
Thermal conductivity factor: K : 0,47 w/m²°c (Thk. 200mm)